Defibrilator Bifazic HeartStart XL M4735A HeartStart XL Defibrillator/Monitor

Specificatii
Defibrillator
Waveform: Biphasic Truncated Exponential. Waveform parameters adjusted
as a function of patient impedance.
Shock Delivery: Via multifunction defib electrode pads, or paddles.
Charge Time: Less than 3 seconds to 200 Joules with a new, fully charged
M3516A SLA battery pack at 25oC.
Less than 15 seconds to 200 Joules when powered by AC with no battery installed.
Patient Impedance Range: 25 to 180 Ohms.
Manual Mode
Manual Output Energy (Delivered): 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150,
200 Joules.
Controls: Manual/AED On/Energyknob, Charge/Disarm, Shock,
ECG Lead Select, SpO2 On/Off, SpO2 Alarms, HR Alarms, Sync On/Off,
Pacer, Pacer Start/Stop, Pacer Rate, Pacer Current, Pacer Mode, ECG Gain,
Volume, Strip, Summary, Mark.
Indicators: EL display for ECG waveform and text prompts, Audio alerts,
QRS Beeper, Charging Tones (for sync and asynchronous modes),
AC Power LED, Battery Charging LED, Sync LED, Pacer LED.
Armed Indicators: Charge done tone and available energy indicated on
display.
Energy Selection: Front panel rotary knob.
Charge Control: Front Panel "2" key or button on paddles.
Table 7-1 Delivered Energy (J) vs. Load Impedance
Selected
Energy
(J)
Load Impedance (ohms)
Accuracy
25 50 100 125 150
2 1.9 2.0 2.1 2.1 2.1 ± 1 J
3 2.8 3.0 3.2 3.2 3.1 ± 2 J
5 4.7 5.0 5.2 5.4 5.2 ± 2 J
7 6.6 7.0 7.3 7.5 7.3 ± 2 J
10 9.3 10.0 10.4 10.7 10.4 ± 2 J
20 18.6 20.0 20.8 21.4 20.8 ± 4 J
30 27.9 30.0 31.2 32.1 31.2 ± 4 J
50 46.7 50.0 52.3 53.5 52.1 ±15%
70 65.4 70.0 73.1 75.0 72.9 ±15%
100 93.5 100.0 104.7 107.2 104.4 ±15%
150 140.3 150.0 156.8 161.0 156.5 ±15%
200 187.0 200.0 209.3 214.6 208.6 ±15%
M4735A Service Manual 7-3
Specifications
7
Shock Control: Front Panel "3" key or buttons on paddles.
Synchronizer: SYNC message appears on the monitor and is annotated on
the printer (if printing while in Sync Mode). An audible beep sounds with
each detected R-wave, while a tick mark on the monitor and printed strip indicate
the discharge points. Synchronizer delay is less than 60 msec from peak
of R-wave to peak current of the defibrillation discharge.
AED Mode
AED Energy Profile: Fixed Energy (150 Joules).
AED Shock Series: 1, 2, 3, or 4 shocks per series.
Shock Series Timer: off, 30, 60, 90, 120, 150, 180, or 210 seconds.
Text and Voice Prompts: Extensive text and audible messages guide user
through protocol.
AED Controls: On, Off, Pause/Resume, Analyze/Stop Analysis, Shock,
Lead Select, SpO2 On/Off, SpO2 Alarms, HR Alarms, ECG Gain, Volume,
Strip, Summary, Mark.
Indicators: EL display for ECG waveform and text prompts, Audio alerts,
Voice prompts, QRS Beeper, Charging Tone, Charge Done Tone, Printer,
AC Power LED, Battery Charging LED.
Armed Indicators: Charge Done Tone, Available Energy indicated on display,
Voice Message.
Patient Analysis: Per protocol, evaluates patient ECG and signal quality to
determine if a shock is appropriate and evaluates connection impedance for
proper defibrillation pad contact.
Shockable Rhythms: Ventricular fibrillation with amplitude 100 uV and
wide complex ventricular tachycardia with rates greater than 150 bpm.
Sensitivity and Specificity: Meets AAMI guidelines.
ECG Monitoring
Inputs: Single channel ECG may be viewed on display and printed. Pads
ECG is obtained through two multifunction defibrillation electrode pads.
Lead I, II, or III are obtained through the 3-lead ECG cable and separate
monitoring electrodes. With a 5-lead cable, leads aVR, aVL, aVF, and any one
of the V (1-6) leads can also be obtained.
Lead Fault: LEADS OFF message and dashed line appear on the display if
an electrode or lead wire becomes disconnected while a lead is selected.
Paddle Fault: NO PADDLES CONNECTED message and dashed line
appear on the display in Manual Mode if paddles become disconnected.
Pad Fault: PADS OFF message and dashed line appear on the display if a pad
becomes disconnected.
Heart Rate Display: Digital readout on display from 15 to 300 bpm, with an
accuracy of ±10%.
Specifications
7-4 Specifications
Heart Rate Alarms: Configurable pairs of low and high heart rate alarm
limits: 30 to 100, 60 to 140, 90 to 160, and 120 to 200 bpm.
Hands Free Defibrillation Patient Cable Length: 7 ft. (2.13 m).
ECG Cable Length: 12 ft. (3.7 m).
Common Mode Rejection: Greater than 90 dB measured per AAMI standard
for cardiac monitors (EC 13).
ECG Size: 2.5, 5, 10, 20, 40 mm/mV.
Frequency Response:
AC Line Filter: 60 Hz/50Hz.
Pads ECG for Display: Monitor (.15-40 Hz) or EMS (1-30 Hz).
Pads ECG for Printer: Monitor (.15-40 Hz) or EMS 1-30 Hz).
Leads ECG for Display: Monitor (.15-40 Hz) or EMS (1-30 Hz).
Leads ECG for Printer: Diagnostic (.05-150 Hz) or EMS (1-30 Hz) or
Monitor (.15-40 Hz).
Patient Isolation (defibrillation proof):
ECG: Type CF
SpO2: Type CF
Defib: Type BF - External paddles/pads
Type CF - Internal paddles
NOTE The HeartStart XL supports two types of Displays, EL or LCD. See
"Identifying the Display Type" on page 5-7 for information.
Display (EL)
Size: 115 mm x 86 mm.
Type: EL - Electroluminescent.
Resolution: 320 x 240 pixels.
Sweep Speed: 25 mm/s nominal (stationary trace; sweeping erase bar).
Viewing Time: 4 seconds.
Display (LCD)
Size: 111.4 mm x 83.5 mm.
Type: LCD - TFT Color Liquid Crystal Display
Resolution: 320 x 240 pixels.
Sweep Speed: 25 mm/s nominal (stationary trace; sweeping erase bar).
Viewing Time: 4 seconds.
M4735A Service Manual 7-5
Specifications
7
Battery
Type: 2 Ah, 12V, rechargeable, Sealed Lead Acid (SLA).
Dimensions: 2.4" (H) x 0.94" (W) x 7.2" (D).
61.7 mm (H) x 23.9 mm (W) x 182 mm (D).
Weight: 1.4 lb. (0.65 kg).
Charge Time:
􀁺 Approximately 3 hours to 90% charge, indicated by LED on front
panel.
􀁺 Approximately 15 hours total to 100%.
Capacity: With a new, fully charged battery at room temperature (25oC):
􀁺 100 minutes ECG monitoring only, or
􀁺 50 full-energy (200 J) discharges, or
􀁺 75 minutes ECG monitoring while pacing (100 mA, 100 ppm).
Battery Indicators: LOW BATTERY message appears on display when at
least 10 minutes of monitoring time and 5 maximum-energy discharges
remain (with a new battery at room temperature - 25oC).
Battery Storage: Should not be stored above 40oC for extended periods of
time.
Unit can be operated using only AC power, with no battery installed.
Thermal Array Printer
Continuous Real Time Strip: User starts and stops the strip. The Print Strip
prints the selected ECG lead with the following data:
HEADER 1: Date, Time, Heart Rate, the SpO2 Value (if available), and
the text "Delayed" if printing has been configured for Delayed Mode.
Prints every 12 seconds.
HEADER 2: Current mode (AED/Manual), Lead, Gain, filter setting, the
text "Sync" (if Sync has been enabled), and Pacer Settings (consisting of
the Pacer Mode, Rate, and Current, if currently pacing the patient). Prints
every 12 seconds, with Header 1.
HEADER 3: Changes in Mode, Gain, Lead, Sync, and Pacer Settings.
FOOTER: Drug Annotations, HR/SpO2 limits on a Limit Alarm, the
Results of Analysis in AED Mode (No Shock Advised, Shock Advised, or
Cannot Analyze), Charging to xxxJ, Shock Delivered, No Shock Delivered,
Disarm, Battery Low.
SYMBOLS: Mark Triangle (for presses of the Mark key), an Alarm Bell
(Alarm Limit Violations), Lightning Bolt (Shock Delivered; followed by
b for biphasic), Vertical stripe Boundaries/Pacer/Sync Tick Marks.
Specifications
7-6 Specifications
Event Printing: Mark key automatically documents ECG and events during
defibrillation episodes. The Mark key can annotate the event with one of the
following labels: Epinephrine (Adrenaline), Atropine, Lidocaine, and Other.
Auto Printing: The printer can be configured to automatically print on Mark,
Charge, Shock and Alarm.
Delayed Printing: The printer can be configured to run real time or with a six
second delay.
Reports: The following can be printed: Event Summary, Configuration,
Extended Self Test, System Log, Battery Capacity Test, Shift/System Check.
Speed: 25 mm/s with an accuracy of ±5%.
Amplitude Accuracy: ±10% or ±50 uV, whichever is greater.
Paper Size: 50 mm by 30 m (100 ft.).
Noninvasive Pacing
Waveform: Monophasic Truncated Exponential.
Current Pulse Amplitude:
Range: 10 mA to 200 mA (5 mA resolution)
Accuracy: 10 mA - 50 mA ±5 mA
50 mA - 200 mA ±10%.
Pulse Width: 20 ms with accuracy +0, -5 ms.
Rate: 30 ppm to 180 ppm (10 ppm increments); accuracy ±1.5%.
Modes: Demand or Fixed Rate.
Refractory Period: 80 ppm: 340 msec ±10%
80 ppm: 240 msec ±10%
SpO2 Pulse Oximetry
Range:
SpO2 - 0 to 100%.
Pulse Rate - 30 to 300 bpm.
Accuracy with:
M1191A sensor - 1 standard deviation 70% to 100%, ± 2.5%
M1192A sensor - 1 standard deviation 70% to 100%, ± 2.5%
M1194A sensor - 1 standard deviation 70% to 100%, ± 4.0%
M1131A sensor - 1 standard deviation 70% to 100%, ± 3.0%
M1903B sensor - 1 standard deviation 70% to 100%, ± 3.0%
M1904B sensor - 1 standard deviation 70% to 100%, ± 3.0%
Pulse Rate Accuracy: 2% or 1 bpm (whichever is greater).
Wavelength Range: 500 to 1000 nm.
M4735A Service Manual 7-7
Specifications
7
Emitted Light Energy: to 15 mW.
DisplayInterval: 60 seconds.
Resolution: 1%.
Sp02 Alarm Limits: Three preset low alarm limits: 90%, 85%, and 80%.
INOP Alerts: Triggered by disconnected sensor, noisy signal, light interference
or low signal (non-pulsatile).
Alarm delay: 10 seconds.
Event Storage
Internal Event Summary:
The internal Event Summary stores up to 300 events and up to 50 waveforms.
Events can be marked with a Mark symbol and, if configured for drug annotation,
the following labels can be added: Epinephrine (Adrenaline in U.K. and
Australia), Atropine, Lidocaine, or Other.
The Summary key on the front panel is used to print the internal Event Summary.
Data Card Event Summary:
The Data Card stores continuous ECG waveforms and events.
General
Dimensions: 19.0 cm (H) x 37.6 cm (W) x 34.6 cm (L)
7.5" x 14.8" x 13.7"
Weight: Standard Configuration weighs 6.5 kg (14.3 lbs.) including battery,
full roll of paper, and external paddles.